速報APP / 工具 / Electrical Power Designer

Electrical Power Designer

價格:免費

更新日期:2019-06-18

檔案大小:1.6M

目前版本:1.0

版本需求:Android 4.0 以上版本

官方網站:http://www.menatech.ca

Email:support@menatech.ca

聯絡地址:MENA TECH 7248 CORRINE CR. MISSISSAUGA, ONTARIO CANADA L5N5C1

Electrical Power Designer(圖1)-速報App

For the electrical engineers who spend a lot of time and effort designing Low voltage power distribution networks and cabling, and going deeply into complex mathematical equations to complete compliant design with accurate calculation.

Now we introduce ELECTRICAL POWER DESIGNER.

Electrical Power Designer(圖2)-速報App

In few words, ELECTRICAL POWER DESIGNER can make all the calculations for cables design, short circuit current for transformer and cables, voltage drop, power factor correction with capacitor bank and performs all calculation for power network project according to international standard.

ELECTRICAL POWER DESIGNER: Has three programs to calculate.

Electrical Power Designer(圖3)-速報App

Power factor correction: To improve the power factor.

You enter the current power factor, the required power factor and the line to line voltage input. You get the capacitor bank value in KVAR, the current before correction, the current after correction, and the current in the capacitor bank.

Electrical Power Designer(圖4)-速報App

Cable design: To calculate the cable cross section area and cable specification.

Choose the power input (KVA, KW, HP, or AMP) and enter the input voltage, load, derating factor, no of parallel cable, choose cable type (XLPE or PVC), (copper or aluminum), Method of installation, cable length, max short circuit current, max voltage drop and max short circuit duration in millisecond. You get cable cross section area, actual voltage drop, max allowed short circuit, and the current per cable.

Electrical Power Designer(圖5)-速報App

Short circuit calculation: To calculate the short circuit from the transformer to the last panel board for up to 4 stages.

You enter input voltage line to line, transformer power in KVA, and the transformer impedance (percentage). You will get the short circuit current on transformer terminal in KA. Then, go to the next stage You will see in the first field the previous result, Then enter the cable size in mm2 using drop down list, the cable conductor (Copper or Aluminum), Cable insulation material (PVC or XLPE), Cable length in meters, and the number of parallel cables. You get total short circuit current at the end of the cable I (in KA) and the short circuit current per cable if you have more than one parallel cable. Then go to the next stage and repeat the previous steps. You can go up to 4 stages.

Electrical Power Designer(圖6)-速報App

The user manual is available on product page.

ELECTRICAL POWER DESIGNER is fully compliant with many international electrical standards and code such as (IEC 60502, IEC 60228, BS 5476, BS 7889, BS 5467 ).

Electrical Power Designer(圖7)-速報App

ELECTRICAL POWER DESIGNER is also flexible enabling the designer to use factors in the calculations according to the requirements of the project and also warn the designer if there is any mal or illogical inputs.

ELECTRICAL POWER DESIGNER is an economic solution for the designer and for the client as well, saving time and effort will eliminate a lot of headache for all parties and expedite the progress of the project.

Electrical Power Designer(圖8)-速報App